Line Voltage Requirements |
115 V, 50/60 Hz 230 V, 50/60 Hz |
Size (Individual Nozzle) |
2.5” high by .87 i” wide by 3.5” long |
Maximum Air Pressure (clean, dry air) |
100 psi maximum |
Air Flow (at 30 psi) |
4.4 SCFM |
Air Supply Connection |
1/8-inch NPT on nozzle |
Working Distance from substrate |
3 inches to 10 inches |
Operating Temperature Limit |
150° F (66° C) |
Static Charge Discharge Time |
0.6 seconds at 6 inches at 30 psi (5000 V to 500V) |
Power Supply |
Part Number |
F167 – 120V, 50/60 Hz, 7 kV, 3mA max, 2 output |
IPF0300 |
F167S – 120V, 50/60 Hz, 7 kV, 3mA max, lighted power switch |
IPF03S0 |
F267 – 230V, 50/60 Hz, 7 kV, 3mA max, 2 output |
IPF0301 |
F267S – 230V, 50/60 Hz, 7 kV, 3mA max, lighted power switch |
IPF03S1 |
N167 – 120V, 60Hz, 7 kV, 3mA max, 4 output |
IPN0519 |
N267 – 230V, 60Hz, 7 kV, 3mA max, 4 output |
IPN0515 |
N257 – 230V, 50Hz, 7 kV, 3mA max, 4 output |
IPN0516 |
Please call us for pricing information or any application questions you may have.