Input Power
|
24 VDC, 30 mA nominal
|
Input Connection
|
via (user supplied) Intrinsic Safety Barriers
|
Input Cable Lengths
|
30 ft (9.1m)
|
Input Purge Gas
|
(for minimizing dust, dirt and contamination in probe aperture
only)
1 to 2.5 psi (7 to 17 kPa) nominal operating pressure
5 psi (35 kPa) max operating pressure
0.14 scfm (4 NL/min) per sensor at 1 psi (5 kPA)
0.22 scfm (6 NL/min) per sensor at 2.5 psi (20 kPa)
Clean, dry, oil-free compressed air or nitrogen
|
Operating Distance*/Voltage
|
2” (50 mm) 20 kV max
3” (75 mm) 25 kV max
4” (100 mm) 30 kV max (factory default setting)
6” (150 mm) 40 kV max
8” (200 mm) 50 kV max
10” (250 mm) 60 kV max
|
Dimensions
|
260L x 32.5W x 44.5H mm [10.25”L x 1.28”H x 1.75”H]
|
Weight
|
0.68 kg [1.5 lb]
|
Enclosure
|
Stainless Steel and Conductive Polyamide
|